CPC6600-MIB DEFINITIONS ::= BEGIN IMPORTS PortList, dot1dStpPortEntry FROM Q-BRIDGE-MIB SnmpAdminString FROM SNMP-FRAMEWORK-MIB TruthValue, RowStatus FROM SNMPv2-TC enterprises, IpAddress, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString FROM RFC1213-MIB; -- "MacAddress" -- A 6 octet address in the "canonical" order defined by IEEE -- 802.1a, i.e., as if it were transmitted least significant -- bit first. MacAddress ::= OCTET STRING (SIZE (6)) FilterMask ::= OCTET STRING (SIZE (64)) -- The status of a file system command table entry. Cpc6600RowStatus ::= INTEGER { valid(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6) } FsCommandStatus ::= INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } FsRemoteFlagType ::= INTEGER { rsh(1), ftp(2) } PortMirrorState ::= INTEGER { enabled(1), disabled(2) } PortMirrorModes ::= INTEGER { bcmMirrorDisable(1), bcmMirrorL2(2), bcmMirrorL3(3) } VlanPortState ::= INTEGER { on(1), off(2), ignore(3) } -- -- Textual Conventions -- (i.e., these conventions do not affect object encoding) -- -- "DURABLE" (Non-Standard): -- Objects that are saved across a system reset and/or power cycle -- are noted as "DURABLE" for convenience in the DESCRIPTION -- section of the object definition. -- -- To define "DURABLE" object "factory default values", use the -- following rules to modify the "DURABLE line(s) in the DESCRIPTION -- section of the object definition (see examples below): -- 1. Curly braces(i.e., '{', '}') containing the default value(s) -- must follow '"DURABLE:' separated by a space or start on -- the next line. -- 2. There must be a space separating the curly brace (left -- or right) and the default value(s). -- 3. Strings are denoted using single quotes (e.g., 'public'). -- Do NOT use single or double quotes within a string. Strings -- also must NOT include curly braces. -- 4. Decimal INTEGER values must NOT use single quotes. -- Hexadecimal and binary values MUST use single quotes -- followed by a lower or upper case character to indicate -- hexadecimal (h) or binary (b) (e.g., 'FACE'H). -- 5. The default value may span more than one line (i.e., parser -- looks for the closing curly brace). Extra white space will -- be removed. If possible, to avoid confusion, put the -- default value on a single line. -- 6. Multiple default values can be included within the curly -- brace set. Multiple values must be separated using commas -- with no preceding or succeeding spaces; it is OK to use -- a 'Return' after the comma to allow the new item to start -- on the next line. Do NOT use a comma after the last -- default value. -- 7. To set all values use ':all' after parameter (e.g., -- enable:all). If ':all' is used on the last value (e.g., -- enable,enable,disable:all), the remaining items are set -- to the last supplied value. -- 8. The actual DESCRIPTION text should start on the next line -- after DURABLE: or, if a default value is used, the next -- line after the right curly brace for the default value. -- 9. DURABLE objects WITHOUT an explicit factory default value -- in curly braces, default to zero, NULL, or the lowest -- enumerated value. This also applies to the remaining -- table entries when only some of the defaults are defined. -- -- Valid Examples: -- decimal INTEGER examples: -- "DURABLE: { 60 } ;single default -- "DURABLE: { 1,3,7,11 } ;4 defaults -- "DURABLE: { 60:all } ;all entries use 60 -- "DURABLE: { 1,2,30:all } ;3rd thru end use 30 -- hexadecimal INTEGER examples: -- "DURABLE: { 'face'h } -- "DURABLE: { 'face'H } -- "DURABLE: { 'face'H:all } -- "DURABLE: { 'deaf'h,'face'h } ;2 defaults -- binary INTEGER examples: -- "DURABLE: { '10101111'b } -- "DURABLE: { '0010110100101101'B } -- enumerated value examples: -- "DURABLE: { disable } -- "DURABLE: { enable,enable } ;2 defaults -- "DURABLE: { enable:all } ;enable all entries -- "DURABLE: { enable,disable:all } ;enable 1st; disable rest -- MacAddress (OCTET STRING) example: -- "DURABLE: { '0123456789ab'H } -- OBJECT IDENTIFIER example: -- "DURABLE: { sysDescr } -- IpAddress example: -- "DURABLE: { 'c0210415'h } -- DisplayString examples: -- "DURABLE: { 'OEM Product' } -- "DURABLE: { 'public','private' } ;2 defaults; rest null -- -- "NONVOLATILE" (Non-Standard): -- Objects that are saved across a system reset and/or power cycle -- and are not owned by this MIB are noted as "NONVOLATILE" for -- convenience in the DESCRIPTION section of the object definition. -- These objects eventually are defined "DURABLE" by some MIB in -- the system and are "passed through" in this MIB. The same -- syntax rules apply to the NONVOLATILE as to the DURABLE. -- ---------------------------------------------------------------------- -- Product Enterprise MIB for PTI CPC6600 24+2 Ethernet Switch. -- pti OBJECT IDENTIFIER ::= { enterprises 1556 } cpc6600 OBJECT IDENTIFIER ::= { pti 7 } -- -- Enterprise (cpc6600) MIB Extensions -- cpc6600CommonGroup OBJECT IDENTIFIER ::= { cpc6600 1 } cpc6600CommonVerGroup OBJECT IDENTIFIER ::= { cpc6600CommonGroup 1 } cpc6600CommonIPGroup OBJECT IDENTIFIER ::= { cpc6600CommonGroup 2 } cpc6600MgmtIPGroup OBJECT IDENTIFIER ::= { cpc6600CommonIPGroup 2 } cpc6600CommonCommToView OBJECT IDENTIFIER ::= { cpc6600CommonGroup 3 } cpc6600CommonAuthGroup OBJECT IDENTIFIER ::= { cpc6600CommonGroup 4 } cpc6600CommonAuthFtpGroup OBJECT IDENTIFIER ::= { cpc6600CommonAuthGroup 1 } cpc6600CommonTrapGroup OBJECT IDENTIFIER ::= { cpc6600CommonGroup 5 } cpc6600CommonLoadGroup OBJECT IDENTIFIER ::= { cpc6600CommonGroup 6 } cpc6600CommonMiscGroup OBJECT IDENTIFIER ::= { cpc6600CommonGroup 7 } cpc6600CommonMiscBootpDHCPGroup OBJECT IDENTIFIER ::= { cpc6600CommonMiscGroup 6 } cpc6600CommonLogGroup OBJECT IDENTIFIER ::= { cpc6600CommonGroup 9 } cpc6600CommonMiscCoSGroup OBJECT IDENTIFIER ::= { cpc6600CommonGroup 10 } cpc6600CommonIgmpSnoop OBJECT IDENTIFIER ::= { cpc6600CommonGroup 11 } cpc6600ArchGroup OBJECT IDENTIFIER ::= { cpc6600 2 } cpc6600ArchIfaceGroup OBJECT IDENTIFIER ::= { cpc6600ArchGroup 1 } cpc6600ArchTrunkGroup OBJECT IDENTIFIER ::= { cpc6600ArchGroup 2 } cpc6600ChipGroup OBJECT IDENTIFIER ::= { cpc6600 3 } cpc6600StpGroup OBJECT IDENTIFIER ::= { cpc6600 4 } cpc6600FsGroup OBJECT IDENTIFIER ::= { cpc6600 5 } cpc6600UsrVarGroup OBJECT IDENTIFIER ::= { cpc6600 6 } cpc6600PortMirrorGroup OBJECT IDENTIFIER ::= { cpc6600 7 } cpc6600PktThresholdGroup OBJECT IDENTIFIER ::= { cpc6600 8 } cpc6600IntegrityTestGroup OBJECT IDENTIFIER ::= { cpc6600 9 } cpc6600SystemInclusiveFilterGroup OBJECT IDENTIFIER ::= { cpc6600 10 } cpc6600UserInclusiveFilterGroup OBJECT IDENTIFIER ::= { cpc6600 11 } cpc6600L3IpMisc OBJECT IDENTIFIER ::= { cpc6600 12 } cpc6600L3IpSubnet OBJECT IDENTIFIER ::= { cpc6600 13 } cpc6600L3IpStatic OBJECT IDENTIFIER ::= { cpc6600 14 } cpc6600L3IpDynamic OBJECT IDENTIFIER ::= { cpc6600 15 } cpc6600L3IpRoute OBJECT IDENTIFIER ::= { cpc6600 16 } cpc6600VlanStpGroup OBJECT IDENTIFIER ::= { cpc6600 17 } cpc6600SecurityGroup OBJECT IDENTIFIER ::= { cpc6600 18 } cpc6600PortGroup OBJECT IDENTIFIER ::= { cpc6600 19 } cpc6600ArpGroup OBJECT IDENTIFIER ::= { cpc6600 20 } cpc6600BeaconGroup OBJECT IDENTIFIER ::= { cpc6600 21 } -- -- -- -- Common Group Begins -- -- -- PTI Extension MIB, Version Group -- -- This group enables the retrieval of version information for -- various components in the system. -- -- Some version numbers have the concept of "Major.Minor" designators. -- In these version numbers, the Major designator represents the -- primary release version, while the Minor designator represents -- the secondary version, incremented for bug-fixes or non-critical -- modifications. For example, the version number 1.2 has "1" as -- the Major version number and "2" as the minor version number. -- cpc6600CommonVerMIBMajor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get this MIB Major version number. This number should match the Major version given in the documentation header in the beginning text of this MIB." ::= { cpc6600CommonVerGroup 1 } cpc6600CommonVerMIBMinor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get this MIB Minor version number. This number should match the Minor version given in the documentation header in the beginning text of this MIB." ::= { cpc6600CommonVerGroup 2 } cpc6600CommonVerMIBPatch OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get this MIB Patch version number. This number should match the Patch version given in the documentation header in the beginning text of this MIB." ::= { cpc6600CommonVerGroup 3 } cpc6600CommonVerBootSWMajor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get the Boot Software Major version number. This number references the CPC6600 Boot ROM module." ::= { cpc6600CommonVerGroup 4 } cpc6600CommonVerBootSWMinor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get the Boot Software Minor version number. This number references the CPC6600 Boot ROM module." ::= { cpc6600CommonVerGroup 5 } cpc6600CommonVerBootSWPatch OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get the Boot Software Patch version number. This number references the CPC6600 Boot ROM module." ::= { cpc6600CommonVerGroup 6 } cpc6600CommonVerAppSWMajor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get the Application Software Major version number. This number references the core Switch Application modules as a whole." ::= { cpc6600CommonVerGroup 7 } cpc6600CommonVerAppSWMinor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get the Application Software Minor version number. This number references the core Switch Application modules as a whole." ::= { cpc6600CommonVerGroup 8 } cpc6600CommonVerAppSWPatch OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get the Application Software Patch version number. This number references the core Switch Application modules as a whole." ::= { cpc6600CommonVerGroup 9 } cpc6600CommonVerBootLoaderMajor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get the Boot Loader Software Major version number." ::= { cpc6600CommonVerGroup 10 } cpc6600CommonVerBootLoaderMinor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get the Boot Loader Software Minor version number." ::= { cpc6600CommonVerGroup 11 } cpc6600CommonVerBootLoaderPatch OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get the Boot Loader Software Patch version number." ::= { cpc6600CommonVerGroup 12 } cpc6600CommonVerBootScriptMajor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get the Boot Script Software Major version number." ::= { cpc6600CommonVerGroup 13 } cpc6600CommonVerBootScriptMinor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get the Boot Script Software Minor version number." ::= { cpc6600CommonVerGroup 14 } cpc6600CommonVerBootScriptPatch OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get the Boot Script Software Minor version number." ::= { cpc6600CommonVerGroup 15 } -- -- CPC6600 Extension MIB, IP Connectivity Information -- -- This group is meant to be a collection of controls and data -- that configure the device for IP connectivity. -- cpc6600MgmtIPIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { '00000000'H } Set IP Address for the device - only applies after reset - see cpc6600CommonMiscReset." ::= { cpc6600MgmtIPGroup 1 } cpc6600MgmtIPNetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 'ffffff00'H } Set IP NetMask for the device - only applies after reset - see cpc6600CommonMiscReset." ::= { cpc6600MgmtIPGroup 2 } cpc6600MgmtLinkState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { enable } The administrative link state of the managment port. Set to enable(1) or disable(2)." ::= { cpc6600MgmtIPGroup 3 } cpc6600MgmtOperLinkState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-only STATUS mandatory DESCRIPTION " The operational link state of the managment port." ::= { cpc6600MgmtIPGroup 4 } cpc6600MgmtDuplexSpeedSet OBJECT-TYPE SYNTAX INTEGER { autonegotiate(1), half-10-noflow(2), full-10-noflow(3), half-100-noflow(4), full-100-noflow(5), half-1000-noflow(6), full-1000-noflow(7), half-10-flow(8), full-10-flow(9), half-100-flow(10), full-100-flow(11), half-1000-flow(12), full-1000-flow(13), illegal(99) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { autonegotiate:all } The desired speed and duplex for the interface. If the selected control is not possible on the interface, a value of (99) illegal is returned. If the port type does NOT support the default of autonegotiate (1), then the application will initialize the port to a valid value (e.g., 1000full (7)). Note that not all controls are possible for all interfaces. For example, only full-1000 (7) is available for Gigabit Ethernet interfaces." ::= { cpc6600MgmtIPGroup 5 } ------------------------------------------------------------------------------ -- -- cpc6600CommonCommToView - SNMP 'Community-to-View' Mapping -- -- SNMP access uses the SNMP-VIEW-BASED-ACM-MIB (RFC2575) for all SNMP -- versions (i.e., v1, v2c and v3). Note that SNMP -- v1 and v2c both use the SNMP 'community string' to implement limited -- security and administrative control. Consequently, to support the -- 'View-based Access Control Model' for SNMPv1/v2c requires a mechanism to -- map the 'community string' to a 'view'. This is implemented using the -- 'cpc6600CommonCommunityToViewTable'. This table allows up to 8 unique -- community strings to be mapped to the same or different views as defined -- in the SNMP-VIEW-BASED-ACM-MIB. Each community can have read-only or -- read-write access permission. -- -- For test and development purposes, the factory default setting includes -- a single 'active(1)' entry for index '1' that contains: -- cpc6600CommonComm2ViewCommName = "public" -- cpc6600CommonComm2ViewViewName = "internet" ==>1.3.6.1 -- cpc6600CommonComm2ViewPermission = "readWrite(2)" -- -- These default settings, in conjunction with a corresponding factory -- default entry in the RFC2575 'vacmViewTreeFamilyTable', allow full GET -- and SET access for the entire 'internet' MIB subtree. Although useful -- for test and development, this is not a desirable default for a -- production switch. -- ------------------------------------------------------------------------------ -- cpc6600CommonCommunityToViewTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600CommonCommunityToViewEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of SNMPv1/v2c community string to view name mappings." ::= { cpc6600CommonCommToView 1 } cpc6600CommonCommunityToViewEntry OBJECT-TYPE SYNTAX Cpc6600CommonCommunityToViewEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of community-to-view parameters." INDEX { cpc6600CommonComm2ViewIndex } ::= { cpc6600CommonCommunityToViewTable 1 } Cpc6600CommonCommunityToViewEntry ::= SEQUENCE { cpc6600CommonComm2ViewIndex Integer32, cpc6600CommonComm2ViewCommName DisplayString, cpc6600CommonComm2ViewViewName SnmpAdminString, cpc6600CommonComm2ViewPermission INTEGER, cpc6600CommonComm2ViewRowStatus Cpc6600RowStatus } cpc6600CommonComm2ViewIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A simple index into 'cpc6600CommonCommunityToViewTable'." ::= { cpc6600CommonCommunityToViewEntry 1 } cpc6600CommonComm2ViewCommName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..20)) MAX-ACCESS read-create STATUS current DESCRIPTION "DURABLE: { 'public','':all } The SNMPv1/v2c community name string. Duplicate community names are not allowed in this table. Note that a null string is not a valid community name (i.e., a null string forces 'cpc6600CommonComm2ViewRowStatus' to 'notReady(3)')." ::= { cpc6600CommonCommunityToViewEntry 2 } cpc6600CommonComm2ViewViewName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(1..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "DURABLE: { 'internet':all } At runtime (i.e., not when this object is SET), this view name is compared to the 'vacmViewTreeFamilyViewName' in the 'vacmViewTreeFamilyTable' (see RFC2575). If a match is found and the varbind(s) specify valid object type and instance, the 'cpc6600CommonComm2ViewPermission' privilege is permitted. Note that a null string is not a valid view name value. Also note that the value of this object does not have to match an existing entry in the 'vacmViewTreeFamilyTable' (if no match, no access is allowed). Note that the factory default value for this object is 'internet', which allows access to the subtree under '1.3.6.1'." ::= { cpc6600CommonCommunityToViewEntry 3 } cpc6600CommonComm2ViewPermission OBJECT-TYPE SYNTAX INTEGER { readOnly(1), readWrite(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "DURABLE: { readWrite:all } This object specifies the type of access allowed. 'readOnly(1)' allows GET operations (i.e., GET, GET-NEXT, GET-BULK) and 'readWrite(2)' allows both GET and SET operations." ::= { cpc6600CommonCommunityToViewEntry 4 } cpc6600CommonComm2ViewRowStatus OBJECT-TYPE SYNTAX Cpc6600RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "DURABLE: This object indicates the status of this entry. A row in this table can be created using the 'createAndGo(4)' (i.e., all parameters must be valid - supplied in a single SNMP PDU or have default values) or the 'createAndWait(5)' action states. Until all parameters are valid for a conceptual row, this object is 'notReady(3)'. All parameters must be valid before this object can be set to 'active(1)'. Any object in a conceptual row can be modified independent of the value of this object (e.g., can be changed while 'active(1)')." ::= { cpc6600CommonCommunityToViewEntry 5 } ------------------------------------------------------------------------------ -- -- cpc6600CommonIgmpSnoop - IGMP Snooping Parameters -- -- This group is used to instrument the Layer 2 IGMP Snooping support. -- ------------------------------------------------------------------------------ -- cpc6600CommonIgmpSnoopEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "DURABLE: { false } Setting this object to true(1) enables IGMP Snooping. Setting it to false(2) disables IGMP Snooping. Note that IGMP Snooping can function with or without GVRP and GMRP enabled." ::= { cpc6600CommonIgmpSnoop 1 } cpc6600CommonIgmpSnoopAlerts OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "DURABLE: { false } Setting this object to true(1) enables the IP Router Alert Option (as defined in RFC2113) for transmitted IGMP packets. Setting it to false(2) disables this option." ::= { cpc6600CommonIgmpSnoop 2 } cpc6600CommonIgmpSnoopAging OBJECT-TYPE SYNTAX Integer32 (30..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "DURABLE: { 300 } The timeout period in seconds for aging out Multicast Groups dynamically learned with IGMP Snooping. Note that aging operates on a per interface per VLAN per multicast group basis." ::= { cpc6600CommonIgmpSnoop 3 } cpc6600CommonIgmpSnoopTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600CommonIgmpSnoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table, which provides IGMP Snooping information, augments the 'dot1qStaticMulticastTable' in the Q-MIB (RFC2674)." ::= { cpc6600CommonIgmpSnoop 4 } cpc6600CommonIgmpSnoopEntry OBJECT-TYPE SYNTAX Cpc6600CommonIgmpSnoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Displays by VLAN, Multicast Group, and Multicast receive port the set of ports enabled to forward Multicast Group traffic as determined by the IGMP Snooping task." AUGMENTS { dot1qStaticMulticastEntry } ::= { cpc6600CommonIgmpSnoopTable 1 } Cpc6600CommonIgmpSnoopEntry ::= SEQUENCE { cpc6600CommonIgmpSnoopEgressPorts PortList } cpc6600CommonIgmpSnoopEgressPorts OBJECT-TYPE SYNTAX PortList MAX-ACCESS read-only STATUS current DESCRIPTION "This read-only object displays the set of ports enabled to forward specific Multicast Group traffic as determined by the IGMP Snooping task. It should be noted that the IGMP Snooping task generates a pseudo-static (i.e., not saved in NVM) port list similar to the RFC2674 Q-MIB 'dot1qStaticMulticastStaticEgressPorts' object. Consequently, a port will not be a member of 'cpc6600CommonIgmpSnoopEgressPorts' if it is a member of 'dot1qStaticMulticastForbiddenEgressPorts'." ::= { cpc6600CommonIgmpSnoopEntry 1 } cpc6600CommonAuthFtpUser OBJECT-TYPE SYNTAX DisplayString (SIZE (1..16)) ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 'ftpuser' } The name of this ftp user." ::= { cpc6600CommonAuthFtpGroup 1 } cpc6600CommonAuthFtpPassword OBJECT-TYPE SYNTAX DisplayString (SIZE (1..16)) ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 'ftpPassword' } The password for this ftp user. For security reasons, you can only query this object with the CLI." ::= { cpc6600CommonAuthFtpGroup 2 } cpc6600CommonAuthTftpdWriteAccess OBJECT-TYPE SYNTAX INTEGER { fullWriteAccess(1), noWriteAccess(2), writeOnlyIfFileExists(3), writeOnlyIfFileDoesNotExist(4) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { fullWriteAccess } The permissions on a tftp operation . Full write access (1). No write access (2). Write only if file already exists (3). Write only if the file does not exist (4)." ::= { cpc6600CommonAuthGroup 6 } -- -- cpc6600 Extension MIB, Trap Group -- -- A "TestTrap" facility is provided to test the trap subsystem. -- See "cpc6600CommonTrapTest". -- cpc6600CommonTrapTest OBJECT-TYPE SYNTAX INTEGER { noop (1), coldstart (2), linkdown (3), linkup (4), authentication (5), cpc6600specific (6) } ACCESS read-write STATUS mandatory DESCRIPTION "This object sends a particular kind of SNMP Trap, as selected by type, to the SNMP manager to verify proper operation of the Trap Subsystem. A GET always returns the noop (1) value." ::= { cpc6600CommonTrapGroup 1 } cpc6600CommonUserDefinedTrapTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600CommonUserDefinedTrapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of the traps a user can specify and send." ::= { cpc6600CommonTrapGroup 2 } cpc6600CommonUserDefinedTrapEntry OBJECT-TYPE SYNTAX Cpc6600CommonUserDefinedTrapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of the traps a user can specify and send." INDEX { cpc6600CommonUserDefinedTrapId } ::= { cpc6600CommonUserDefinedTrapTable 1 } Cpc6600CommonUserDefinedTrapEntry ::= SEQUENCE { cpc6600CommonUserDefinedTrapId INTEGER, cpc6600CommonUserDefinedTrapTime TimeTicks, cpc6600CommonUserDefinedTrapString OCTET STRING, cpc6600CommonUserDefinedTrapRowStatus RowStatus } cpc6600CommonUserDefinedTrapId OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The unique identifier allocated to this trap entry." ::= { cpc6600CommonUserDefinedTrapEntry 1 } cpc6600CommonUserDefinedTrapTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time at which this trap will be sent, ie. when the user sets 'cpc6600CommonUserDefinedTrapRowStatus' to 'active(1)'." ::= { cpc6600CommonUserDefinedTrapEntry 2 } cpc6600CommonUserDefinedTrapString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The string that will be a variable binding in this trap, to be used however the user needs." ::= { cpc6600CommonUserDefinedTrapEntry 3 } cpc6600CommonUserDefinedTrapRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the status of this entry. A row in this table can be created using the 'createAndWait(5)'action state. Until all parameters are valid for a conceptual row, this object is 'notReady(3)'. All parameters must be valid in this table and the 'cpc6600CommonUserDefinedTrapVarBindTable' before this object can be set to 'active(1)'." ::= { cpc6600CommonUserDefinedTrapEntry 4 } cpc6600CommonUserDefinedTrapVarBindTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600CommonUserDefinedTrapVarBindEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of the traps' variable bindings a user can specify and send." ::= { cpc6600CommonTrapGroup 3 } cpc6600CommonUserDefinedTrapVarBindEntry OBJECT-TYPE SYNTAX Cpc6600CommonUserDefinedTrapVarBindEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of the traps' variable bindings a user can specify and send." INDEX { cpc6600CommonUserDefinedTrapId, cpc6600CommonUserDefinedTrapVarBindIndex } ::= { cpc6600CommonUserDefinedTrapVarBindTable 1 } Cpc6600CommonUserDefinedTrapVarBindEntry ::= SEQUENCE { cpc6600CommonUserDefinedTrapVarBindIndex INTEGER, cpc6600CommonUserDefinedTrapObjectName DisplayString, cpc6600CommonUserDefinedTrapVariable OBJECT IDENTIFIER, cpc6600CommonUserDefinedTrapDataType INTEGER, cpc6600CommonUserDefinedTrapOctetStrValue OCTET STRING, cpc6600CommonUserDefinedTrapIntegerValue INTEGER, cpc6600CommonUserDefinedTrapVarBindRowStatus RowStatus } cpc6600CommonUserDefinedTrapVarBindIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The unique identifier allocated to this trap's Variable Bind entry." ::= { cpc6600CommonUserDefinedTrapVarBindEntry 1 } cpc6600CommonUserDefinedTrapObjectName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of the variable binding with this user defined trap." ::= { cpc6600CommonUserDefinedTrapVarBindEntry 2 } cpc6600CommonUserDefinedTrapVariable OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "The object's identifier with instance to include as a variable binding with this user defined trap." ::= { cpc6600CommonUserDefinedTrapVarBindEntry 3 } cpc6600CommonUserDefinedTrapDataType OBJECT-TYPE SYNTAX INTEGER { string-value (1), integer-value (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The data type this object identifier to include as a variable binding with this user defined trap." ::= { cpc6600CommonUserDefinedTrapVarBindEntry 4 } cpc6600CommonUserDefinedTrapOctetStrValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The octet string value for this object identifier to include as a variable binding with this user defined trap." ::= { cpc6600CommonUserDefinedTrapVarBindEntry 5 } cpc6600CommonUserDefinedTrapIntegerValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The integer value for this object identifier to include as a variable binding with this user defined trap." ::= { cpc6600CommonUserDefinedTrapVarBindEntry 6 } cpc6600CommonUserDefinedTrapVarBindRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the status of this entry. A row in this table can be created using the 'createAndWait(5)'action state. Until all parameters are valid for a conceptual row, this object is 'notReady(3)'. All parameters must be valid before this object can be set to 'active(1)'. Setting this object to 'active(1)' will cause a trap to be sent to the SNMP Client." ::= { cpc6600CommonUserDefinedTrapVarBindEntry 7 } -- -- PTI Private Extension MIB, Load TFTP Group -- -- This group is meant to be a collection of controls and data -- that determine the file download and upload configuration -- and mode. -- cpc6600CommonLoadTftpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: Set IP Address for the TFTP server used for downloading and uploading files." ::= { cpc6600CommonLoadGroup 1 } cpc6600CommonLoadTftpFileName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: Set TFTP file path and name." ::= { cpc6600CommonLoadGroup 2 } cpc6600CommonLoadType OBJECT-TYPE SYNTAX INTEGER { application(1), boot(2), configuration(3) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { application } The type of file to download or upload upon an cpc6600CommonLoadExecute. WARNING: The boot should only be downloaded when absolutely required (e.g., if power is removed during the boot Flash write operation, the agent cannot be recovered)." ::= { cpc6600CommonLoadGroup 3 } cpc6600CommonLoadExecute OBJECT-TYPE SYNTAX INTEGER { noop(1), -- no operation download(2), -- Application, Boot, or Configuration upload(3) -- Configuration only } ACCESS read-write STATUS mandatory DESCRIPTION "Execute file download or upload procedure. A SET of this object starts the load procedure. Note that the Application and Boot images can only be downloaded. The Configuration file can be uploaded and downloaded. A GET of this object will return a noop (1). Use cpc6600CommonLoadExecuteStatus to determine the status of the executed load." ::= { cpc6600CommonLoadGroup 4 } cpc6600CommonLoadExecuteStatus OBJECT-TYPE SYNTAX INTEGER { not-started(1), in-progress(2), success(3), error-connection(4), error-filename(5), error-fault(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Provides status on the execute file load procedure. The status return is given by one of the enumerated codes not-started (download has not yet started) in-progress (download has not yet finished) success (download has finished successfully) error-connection (download cannot connect) error-filename (download has bad image path/filename) error-fault (download has fault condition on device)." ::= { cpc6600CommonLoadGroup 5 } -- -- PTI Private Extension MIB, Miscellaneous Information -- -- This group is meant to be a collection of controls and data -- that do not require a group of their own, or fall into the -- category of "miscellaneous". -- cpc6600CommonMiscSaveToNvm OBJECT-TYPE SYNTAX INTEGER { noop(1), -- no operation save(2), -- save all configuration parameters to NVM in-progress(3) -- save not yet finished } ACCESS read-write STATUS mandatory DESCRIPTION "When set to save (2), all nonvolatile configuration parameters are saved to NVM (Nonvolatile Memory). NVM save operations may be slow (e.g., erasing/writing Flash device). Consequently, all (or many) updates should be made before saving to NVM. A get operation returns noop (1) or a in-progress(3)." ::= { cpc6600CommonMiscGroup 1 } cpc6600CommonMiscSnmpSecurityOnOff OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "NONVOLATILE: { disable } Enable/Disable SNMP Security. A (1) enables, a (2) disables. This object controls the application of the Community and Host tables. WARNING: If SNMP security is disabled, ANY HOST has ACCESS to the SNMP agent. See cpc6600CommonAuthenGroup and cpc6600CommonTrapGroup." ::= { cpc6600CommonMiscGroup 2 } cpc6600CommonMiscSpanOnOff OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { enable } Enable/Disable Spanning Tree. A (1) enables, a (2) disables. When disabled, the ports of the device are placed in the forwarding mode, regardless of mandatory Spanning Tree state. When re-enabled, the normal state transitions take place." ::= { cpc6600CommonMiscGroup 3 } cpc6600CommonMiscBOOTPOnOff OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { disable } Enable/Disable BOOTP operation. A (1) enables, a (2) disables. When disabled, no BOOTPs are transmitted by the Application. When enabled, the Application sends up to 3 BOOTP requests at 5 second intervals." ::= { cpc6600CommonMiscGroup 4 } cpc6600CommonMiscBOOTPTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 10 } BOOTP operation timeout period to wait for reply at initialization if BOOTP is enabled. Timeout is a decimal integer representing time in seconds. NOTE: The value of zero for this object, means wait forever for a response." ::= { cpc6600CommonMiscGroup 5 } cpc6600CommonMiscBootpDHCPVid OBJECT-TYPE SYNTAX INTEGER (1..4094) ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 1 } BOOTP or DHCP client vlan id." ::= { cpc6600CommonMiscBootpDHCPGroup 1 } cpc6600CommonMiscBootpDHCPifIndex OBJECT-TYPE SYNTAX INTEGER (17825793..17825808) ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 17825793 } BOOTP or DHCP client sw interface index number." ::= { cpc6600CommonMiscBootpDHCPGroup 2 } cpc6600CommonMiscDHCPClientID OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..254)) ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { ' ' } DHCP client identifier is an option used by DHCP clients to specify their unique identifier. DHCP servers use this value to index their database of address bindings. This value is expected to be unique for all clients in an administrative domain. For correct identification of clients, each client's client- identifier MUST be unique among the client-identifiers used on the subnet to which the client is attached. The clientID is composed of a Type value and a sequence of octets that make the client-identifier. The first octet of this parameter will be used as the Type value. The remaining octets are used as the identifier. The clientID MAY contain embedded zeros. It is NOT treated as an ASCII string. Type Client-Identifier +-----+-----+-----+--- | t1 | i1 | i2 | ... +-----+-----+-----+--- ." ::= { cpc6600CommonMiscGroup 7 } cpc6600CommonMiscDHCPClientRetries OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 4 } DHCP client operation retries this many times to receive a response from the server. NOTE: The value of zero for this object, means wait forever for a response." ::= { cpc6600CommonMiscGroup 8 } cpc6600CommonMiscSwitchDHCPClientOnOff OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { disable } Enable/Disable Switch DHCP Client operation. A (1) enables, a (2) disables. When disabled, no DHCPs are transmitted by the Application. When enabled, the Application sends up to 3 DHCP requests at 5 second intervals." ::= { cpc6600CommonMiscGroup 9 } cpc6600CommonMiscMgmtDHCPClientOnOff OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { disable } Enable/Disable Mgmt DHCP Client operation. A (1) enables, a (2) disables. When disabled, no DHCPs are transmitted by the Application. When enabled, the Application sends up to 3 DHCP requests at 5 second intervals." ::= { cpc6600CommonMiscGroup 10 } cpc6600CommonMiscDHCPClientListenOnPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 68 } DHCP Client operations listen on this port number." ::= { cpc6600CommonMiscGroup 11 } cpc6600CommonMiscDHCPClientTransmitToPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 67 } DHCP Client operations transmit to this port." ::= { cpc6600CommonMiscGroup 12 } cpc6600CommonMiscDHCPClientSIAD OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "DHCP Client received configuration from this SIAD (server ip address)." ::= { cpc6600CommonMiscGroup 13 } cpc6600CommonMiscDHCPClientFile OBJECT-TYPE SYNTAX DisplayString (SIZE (1..255)) ACCESS read-write STATUS mandatory DESCRIPTION "DHCP Client received configuration file." ::= { cpc6600CommonMiscGroup 14 } cpc6600CommonMiscDHCPServerOnOff OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { enable } Enable/Disable DHCP Server operation. A (1) enables, a (2) disables. When disabled, no DHCPs are transmitted by the Application. When enabled, the Application reads the configuration file described by the cpc6600CommonMiscDHCPServerConfigFile and serves up IP's to DHCP Clients." ::= { cpc6600CommonMiscGroup 15 } cpc6600CommonMiscDHCPServerConfigFile OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 'flash:/dhcps.conf' } File name of DHCP Server configuration file." ::= { cpc6600CommonMiscGroup 16 } cpc6600CommonMiscBaud OBJECT-TYPE SYNTAX INTEGER { baud2400(1), baud9600(2), baud19200(3), baud38400(4) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 4 } The Serial port BAUD Rate. Attributes are 8 Start Bits, no parity and 1 stop bits (8N1) and Hardware Flow Control. Valid values are 2400, 9600, 19200, and 38400." ::= { cpc6600CommonMiscGroup 17 } cpc6600CommonMiscPassword OBJECT-TYPE SYNTAX DisplayString (SIZE (1..16)) ACCESS not-accessible STATUS mandatory DESCRIPTION "DURABLE: { 'password' } For security reasons, this system password can only be managed with the CLI command 'password'." ::= { cpc6600CommonMiscGroup 18 } cpc6600CommonMiscProductName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..32)) ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 'PTI CPC6600 24/2' } Get and Set the product name of this agent's device. This name is shown in user interface screens." ::= { cpc6600CommonMiscGroup 19 } cpc6600CommonMiscSerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get the serial number of this device." ::= { cpc6600CommonMiscGroup 20 } cpc6600CommonMiscWatchdogRebootOnOff OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { disable } Enable/Disable Watchdog on reset operation. A (1) enables, a (2) disables." ::= { cpc6600CommonMiscGroup 21 } cpc6600CommonMiscWatchdogOnOff OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { enable } Enable/Disable Watchdog operation. A (1) enables, a (2) disables." ::= { cpc6600CommonMiscGroup 22 } cpc6600CommonMiscReset OBJECT-TYPE SYNTAX INTEGER { noop(1), -- no operation reset(2), -- reset unit reset-to-defaults(3) -- reset to factory defaults -- and then reset unit } ACCESS read-write STATUS mandatory DESCRIPTION "Physically performs a hardware reset of the unit. Use with care. A reset (2) resets the unit, a reset-to-defaults (3) resets the nonvolatile configuration to factory defaults and then resets the unit, and noop (1) does nothing. A value of noop (1) is always returned for a GET operation." ::= { cpc6600CommonMiscGroup 23 } cpc6600CommonMiscMaster OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if this cpc6600 is acting in Master mode." ::= { cpc6600CommonMiscGroup 24 } cpc6600CommonMiscBCMrevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the revision of the Broadcom Chip of this cpc6600." ::= { cpc6600CommonMiscGroup 25 } cpc6600CommonMiscSlotID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the slot ID of this cpc6600." ::= { cpc6600CommonMiscGroup 26 } cpc6600CommonMiscLimID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Returns the 8 bit idenitfier for the rear transition LIM module." ::= { cpc6600CommonMiscGroup 27 } cpc6600CommonMiscJumpers OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the settings of the User Definable Jumpers. A value of zero in a bit position indicates that the jumper is installed. A value of 1 indicates that the jumper plug is not installed. Bit 0 - ESS mode jumper. Bit 1 - User Defined Jumper 1. Bit 2 - User Defined Jumper 2. Bit 3 - User Defined Jumper 3. Bits 4-7 are not defined." ::= { cpc6600CommonMiscGroup 28 } cpc6600CommonMiscLIMJumpers OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the value of the configuration for the LIM Jumpers on the Rear Transition Module, or zero for notSupported." ::= { cpc6600CommonMiscGroup 29 } cpc6600CommonMiscShelfID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "IF the LIM installed provides it, this object is the five-bit shelf address or zero for notSupported." ::= { cpc6600CommonMiscGroup 30 } cpc6600CommonSysHsLed OBJECT-TYPE SYNTAX INTEGER { sysHsLedOn(1), sysHsLedOff(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the user to control the hot swap LED." ::= { cpc6600CommonMiscGroup 31 } cpc6600CommonSysStatusFault OBJECT-TYPE SYNTAX INTEGER { statusAmber-faultOff(1), statusGreen-faultOff(2), statusOff-faultRed(3), statusGreen-faultGreen(4), statusGreen-faultRed(5), statusOff-faultGreen(6), statusOff-faultOff(7) } ACCESS read-write STATUS mandatory DESCRIPTION "If this object is set to status_amber-fault_off(1) this represents the system switch is not alive and switch fault is off. If status_green-fault_off(2) is set, the system switch is alive and system switch fault is off. If the status_off-fault_red(3) is set, the system switch fault is on. This has been expanded to illuminate the specified LED (status and system)" ::= { cpc6600CommonMiscGroup 32 } cpc6600CommonMiscClearARL OBJECT-TYPE SYNTAX INTEGER { noop(1), -- no operation clear(2) -- clear arl table } ACCESS read-write STATUS mandatory DESCRIPTION "Flushes the arl table when set to clear(2). A value of noop (1) is always returned for a GET operation." ::= { cpc6600CommonMiscGroup 33 } cpc6600CommonMiscTftpTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 5 } Indicates time in seconds for total time to try sending a single tftp block." ::= { cpc6600CommonMiscGroup 34 } cpc6600CommonMiscTftpReXmit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 2 } Indicates time in seconds to delay between retries of sending a single tftp block." ::= { cpc6600CommonMiscGroup 35 } cpc6600CommonMiscTftpdMaxConnections OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 10 } Indicates the maximum number of simultaneously allowed TFTP connections." ::= { cpc6600CommonMiscGroup 36 } cpc6600CommonMiscWebOnOff OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { enable } Enable/Disable Web management operation. A (1) enables, a (2) disables." ::= { cpc6600CommonMiscGroup 37 } cpc6600CommonMiscLacOnOff OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { disable } Enable/Disable Link Aggregation operation. A (1) enables, a (2) disables." ::= { cpc6600CommonMiscGroup 38 } cpc6600CommonMiscLacPathCostAlgorithm OBJECT-TYPE SYNTAX INTEGER { ftPathCost(1), maxSpeedPathCost(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { maxSpeedPathCost } Aggregated ports will operate at a speed dependant on the number of aggregated links. Spanning Tree uses the speed of a link to determine the best path to the Root. Aggregated Links offer an improvement in Fault Tolerance over a single highspeed link. It may be desirable to artificially give a link aggregate a lower path cost over that of a single higher speed port in order to allow the aggregated link to be used for traffic toward the root. This object selects the algorithm to be applied to the aggregated ports to determine what the port path cost will be. Two algorithms are supported. A (1) ftPathCost, will use a fault tolerant scheme, while a (2) maxSpeedPathCost, will be utilized to determine path cost based on maximum speed of the link. When ftPathCost is selected, an aggregation of seven links will have a better path cost than that of a single port that is ten times the speed of one of the ports in the aggregation. eg. (7) 100M aggregated ports will have a path cost better than a single 1000M port." ::= { cpc6600CommonMiscGroup 39 } cpc6600CommonMiscFtpLogLevel OBJECT-TYPE SYNTAX INTEGER { noLogging(1), logErrorsOnly(2), logAllActivity(3) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { noLogging } Set up ftp logging operation. A (1) means no logging, a (2) means only error messages will be logged, and (3) means all activity will be logged." ::= { cpc6600CommonMiscGroup 40 } cpc6600CommonMiscTftpdLogLevel OBJECT-TYPE SYNTAX INTEGER { noLogging(1), logErrorsOnly(2), logAllActivity(3) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { noLogging } Set up tftpd logging operation. A (1) means no logging, a (2) means only error messages will be logged, and (3) means all activity will be logged." ::= { cpc6600CommonMiscGroup 41 } cpc6600CommonMiscDHCPLogLevel OBJECT-TYPE SYNTAX INTEGER { noLogging(1), logErrorsOnly(2), logAllActivity(3) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { noLogging } Set up DHCP logging operation. A (1) means no logging, a (2) means only error messages will be logged, and (3) means all activity will be logged." ::= { cpc6600CommonMiscGroup 42 } cpc6600CommonMiscVersionString OBJECT-TYPE SYNTAX DisplayString (SIZE (1..32)) ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { '0.0.0' } This is the version of the application whose configuration is stored in the durable file." ::= { cpc6600CommonMiscGroup 43 } cpc6600CommonMiscVRRPOverride OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { enable } This option will override the protocol specification for VRRP's advertisement interval. It will allow the user to manage the advertisement interval by deciseconds instead of seconds. So when configuring the advertisement interval ( 1 - 255 ), the switch will interpret these values as deciseconds not seconds. In order to use this function, the user must not have any instances of VRRP configured. The argument is a boolean to enable(1) / disable(2). NOTE: THIS WILL VIOLATE THE VRRP PROTOCOL AND WILL NOT BE INTEROPERABLE WITH OTHER VENDORS IMPLEMENTATIONS. USE WITH CAUTION." ::= { cpc6600CommonMiscGroup 44 } cpc6600CommonMiscVRRPMasterDownIntervalCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 3 } The VRRP rfc2338 describes Master_Down_Interval as 'Time interval for Backup to declare Master down (seconds). Calculated as: (3 * Advertisement_Interval) + Skew_time'. This object allows the user to replace that '3' with another integer. NOTE: THIS WILL VIOLATE THE VRRP PROTOCOL AND MAY NOT BE INTEROPERABLE WITH OTHER VENDORS IMPLEMENTATIONS. USE WITH CAUTION." ::= { cpc6600CommonMiscGroup 45 } cpc6600CommonMiscDateTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Get or Set the system time and date. The value is expressed in number of UTC seconds since January 1, 1900." ::= { cpc6600CommonMiscGroup 46 } cpc6600CommonMiscLearningModeTable OBJECT-TYPE SYNTAX SEQUENCE OF CPC6600CommonMiscLearningModeTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of learning criteria for each port." ::= { cpc6600CommonMiscGroup 47 } cpc6600CommonMiscLearningModeTableEntry OBJECT-TYPE SYNTAX CPC6600CommonMiscLearningModeTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A unique entry for each port of learning criteria." INDEX { cpc6600CommonMiscLearningModeIndex } ::= { cpc6600CommonMiscLearningModeTable 1 } CPC6600CommonMiscLearningModeTableEntry ::= SEQUENCE { cpc6600CommonMiscLearningModeIndex INTEGER, cpc6600CommonMiscLearningMode INTEGER } cpc6600CommonMiscLearningModeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "An index that uniquely identifies this ports learning mode criteria." ::= { cpc6600CommonMiscLearningModeTableEntry 1 } cpc6600CommonMiscLearningMode OBJECT-TYPE SYNTAX INTEGER { learn-all(1), static-flood(2), static-drop(3) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { learn-all } This object controls how a packet that is learned on this port entry will be handled." ::= { cpc6600CommonMiscLearningModeTableEntry 2 } cpc6600UserName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "DURABLE: { 'admin' } The username to be provided upon switch login. Length is up to 16 chararacters." ::= { cpc6600CommonMiscGroup 48 } cpc6600SSHDEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "DURABLE: { 'disable' } The secure shell and secure ftp fetures can be enabled(1) or disabled(2) with this object." ::= { cpc6600CommonMiscGroup 49 } cpc6600SSHDPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "DURABLE: { '22' } The secure shell TCP port number." ::= { cpc6600CommonMiscGroup 50 } cpc6600CommonLogConsoleLogging OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { enable } When set to enable (1), console logging is enabled. A set to disable(2) disables console logging." ::= { cpc6600CommonLogGroup 1 } cpc6600CommonLogToFile OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { disable } When set to enable (1), file logging is enabled. A set to disable(2) disables file logging." ::= { cpc6600CommonLogGroup 2 } cpc6600CommonLogToFileName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 'flash:/log.msg' } When cpc6600CommonLogToFile is enabled this is the file where the messages are stored." ::= { cpc6600CommonLogGroup 3 } cpc6600CommonLogRemoteDestTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600CommonLogRemoteDestEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of remote host destinations for log files" ::= { cpc6600CommonLogGroup 4 } cpc6600CommonLogRemoteDestEntry OBJECT-TYPE SYNTAX Cpc6600CommonLogRemoteDestEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An instance in the list of remote hosts to be a log destination." INDEX { cpc6600CommonLogRemoteDestIndex } ::= { cpc6600CommonLogRemoteDestTable 1 } Cpc6600CommonLogRemoteDestEntry ::= SEQUENCE { cpc6600CommonLogRemoteDestIndex INTEGER, cpc6600CommonLogRemoteDestIP IpAddress, cpc6600CommonLogRemoteDestOn INTEGER } cpc6600CommonLogRemoteDestIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this remote location as a destination to receive log messages." ::= { cpc6600CommonLogRemoteDestEntry 1 } cpc6600CommonLogRemoteDestIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { '00000000'H } The IP address of the remote host machine for this entry to receive log messages." ::= { cpc6600CommonLogRemoteDestEntry 2 } cpc6600CommonLogRemoteDestOn OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { disable } When set to enable(1), the messages will be logged and sent to the remote destination IP for this entry." ::= { cpc6600CommonLogRemoteDestEntry 3 } cpc6600CommonMiscCOStype OBJECT-TYPE SYNTAX INTEGER { strictPriority(1), weightedRoundRobin(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 1 } These are the possible scheduling algorithm types used in Class of Service egress port priority queues. If the user sets this object to strictPriority(1), then the highest priority queue is serviced first. Low priority queues could be starved of service if there are always non-empty high priority queues in this scheme. Setting this object to weightedRoundRobin(2), has the queues serviced in a round robin fashion, servicing each in turn by weight." ::= { cpc6600CommonMiscCoSGroup 1 } cpc6600CommonMiscCOSqueueWeightTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600CommonMiscCOSqueueWeightEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of weighting values applied to the four priority queues when the COS type is weightedRoundRobin or roundRobinBoundedDelay" ::= { cpc6600CommonMiscCoSGroup 2 } cpc6600CommonMiscCOSqueueWeightEntry OBJECT-TYPE SYNTAX Cpc6600CommonMiscCOSqueueWeightEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the list of weight values for Class of Service." INDEX { cpc6600CommonMiscCOSqueueWeightIndex } ::= { cpc6600CommonMiscCOSqueueWeightTable 1 } Cpc6600CommonMiscCOSqueueWeightEntry ::= SEQUENCE { cpc6600CommonMiscCOSqueueWeightIndex INTEGER, cpc6600CommonMiscCOSqueueWeightValue INTEGER } cpc6600CommonMiscCOSqueueWeightIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this queue." ::= { cpc6600CommonMiscCOSqueueWeightEntry 1 } cpc6600CommonMiscCOSqueueWeightValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 0:all } The weight applied to this priority queue entry. This value defines the maximum number of packets serviced from the particular queue before servicing the next queue." ::= { cpc6600CommonMiscCOSqueueWeightEntry 2 } -- -- Common Group Ends -- -- -- Architecture Group Begins -- -- -- PTI Private Extension MIB, Architecture Group, Interface Info -- -- This group provides interface control and information not easily -- available from other MIBs. -- -- cpc6600ArchIfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600ArchIfaceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Interfaces and their properties" ::= { cpc6600ArchIfaceGroup 1 } cpc6600ArchIfaceEntry OBJECT-TYPE SYNTAX Cpc6600ArchIfaceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An index of interfaces." INDEX { cpc6600ArchIfaceUnit, cpc6600ArchIfacePort } ::= { cpc6600ArchIfaceTable 1 } Cpc6600ArchIfaceEntry ::= SEQUENCE { cpc6600ArchIfaceUnit INTEGER, cpc6600ArchIfacePort INTEGER, cpc6600ArchIfaceLogicalPort INTEGER, cpc6600ArchIfaceName DisplayString, cpc6600ArchIfaceType INTEGER, cpc6600ArchIfaceEnable INTEGER, cpc6600ArchIfaceSTPEnable INTEGER, cpc6600ArchIfaceLink INTEGER, cpc6600ArchIfaceLinkAdmin INTEGER, cpc6600ArchIfaceDuplexSpeedSet INTEGER, cpc6600ArchIfaceDuplexSpeedGet INTEGER, cpc6600ArchIfaceTXOctetsNoErr INTEGER, cpc6600ArchIfaceTXPacketsNoErr INTEGER, cpc6600ArchIfaceRXOctetsNoErr INTEGER, cpc6600ArchIfaceRXPacketsNoErr INTEGER } cpc6600ArchIfaceUnit OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS not-accessible STATUS mandatory DESCRIPTION "An index that uniquely identifies a unit in the Interface Table." ::= { cpc6600ArchIfaceEntry 1 } cpc6600ArchIfacePort OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS not-accessible STATUS mandatory DESCRIPTION "An index that uniquely identifies a port within the unit in the Interface Table." ::= { cpc6600ArchIfaceEntry 2 } cpc6600ArchIfaceLogicalPort OBJECT-TYPE SYNTAX INTEGER (1..128) ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies a port in the Interface Table. This is a linear port number that may may have holes (e.g., missing units). For this MIB, 32 port numbers are reserved for each unit in the stack. For example, port 101 is unit 4, port 5" ::= { cpc6600ArchIfaceEntry 3 } cpc6600ArchIfaceName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..16)) ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: The textual name of this interface, e.g., 'John'." ::= { cpc6600ArchIfaceEntry 4 } cpc6600ArchIfaceType OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following regular1822(2), hdh1822(3), ddn-x25(4), rfc877-x25(5), ethernet-csmacd(6), iso88023-csmacd(7), iso88024-tokenBus(8), iso88025-tokenRing(9), iso88026-man(10), starLan(11), proteon-10Mbit(12), proteon-80Mbit(13), hyperchannel(14), fddi(15), lapb(16), sdlc(17), ds1(18), -- T-1 e1(19), -- european equiv. of T-1 basicISDN(20), primaryISDN(21), -- proprietary serial propPointToPointSerial(22), ppp(23), softwareLoopback(24), eon(25), -- CLNP over IP [11] ethernet-3Mbit(26), nsip(27), -- XNS over IP slip(28), -- generic SLIP ultra(29), -- ULTRA technologies ds3(30), -- T-3 sip(31), -- SMDS frame-relay(32) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of interface, repeated here from the definitions in RFC1213 as a matter of convenience." ::= { cpc6600ArchIfaceEntry 5 } cpc6600ArchIfaceEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION " Enable (1) and Disable (2) control for the interface." ::= { cpc6600ArchIfaceEntry 6 } cpc6600ArchIfaceSTPEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { enable:all } Enable (1) and Disable (2) Spanning Tree Protocol operation for this interface. STP PDUs will not be generated or processed on the interface. Other traffic will be switched normally." ::= { cpc6600ArchIfaceEntry 7 } cpc6600ArchIfaceLink OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of Link Detect on the interface. Set the value up(1) or down(2)." ::= { cpc6600ArchIfaceEntry 8 } cpc6600ArchIfaceLinkAdmin OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "DURABLE: { up:all } The administrative state of Link on this interface." ::= { cpc6600ArchIfaceEntry 9 } cpc6600ArchIfaceDuplexSpeedSet OBJECT-TYPE SYNTAX INTEGER { autonegotiate(1), half-10-noflow(2), full-10-noflow(3), half-100-noflow(4), full-100-noflow(5), half-1000-noflow(6), full-1000-noflow(7), half-10-flow(8), full-10-flow(9), half-100-flow(10), full-100-flow(11), half-1000-flow(12), full-1000-flow(13), illegal(99) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { autonegotiate:all } The desired speed and duplex for the interface. If the selected control is not possible on the interface, a value of (99) illegal is returned. If the port type does NOT support the default of autonegotiate (1), then the application will initialize the port to a valid value (e.g., 1000full (6)). Note that not all controls are possible for all interfaces. For example, only full-1000 (6) is available for fiber Gigabit Ethernet interfaces." ::= { cpc6600ArchIfaceEntry 10 } cpc6600ArchIfaceDuplexSpeedGet OBJECT-TYPE SYNTAX INTEGER { unknown(1), half-10(2), full-10(3), half-100(4), full-100(5), half-1000(6), full-1000(7), illegal(99) } ACCESS read-only STATUS mandatory DESCRIPTION "The actual speed and duplex for the interface. If the interface is not configured to one of the acceptable values, a value of illegal (99) is returned." ::= { cpc6600ArchIfaceEntry 11 } cpc6600ArchIfaceTXOctetsNoErr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of octets transmitted from the interface. This number does not include octets in error." ::= { cpc6600ArchIfaceEntry 12 } cpc6600ArchIfaceTXPacketsNoErr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets transmitted from the interface. This number does not include packets in error." ::= { cpc6600ArchIfaceEntry 13 } cpc6600ArchIfaceRXOctetsNoErr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of octets received on the interface. This number does not include octets in error." ::= { cpc6600ArchIfaceEntry 14 } cpc6600ArchIfaceRXPacketsNoErr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received on the interface. This number does not include packets in error." ::= { cpc6600ArchIfaceEntry 15 } -- ------------------------------------------------------------- -- Architecture Group Ends -- ------------------------------------------------------------- -- ------------------------------------------------------------- -- The PTI Link Aggregator Trunk Group Table -- ------------------------------------------------------------- cpc6600TrunkGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF cpc6600TrunkGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains the Trunk Group Table Entry rule that defines the distribution algorithm for every Link Aggregator that is associated with this System." ::= { cpc6600ArchTrunkGroup 1 } cpc6600TrunkGroupTableEntry OBJECT-TYPE SYNTAX cpc6600TrunkGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of the rules applied to the entries of the Trunk Group Table parameters. This is indexed by the ifIndex of the Aggregator, which is also the dot3adAggIndex." INDEX { cpc6600TrunkGroupTableAggIndex } ::= { cpc6600TrunkGroupTable 1 } cpc6600TrunkGroupEntry ::= SEQUENCE { cpc6600TrunkGroupTableAggIndex INTEGER, cpc6600TrunkGroupTableRule INTEGER } cpc6600TrunkGroupTableAggIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The unique identifier allocated to this Aggregator by the local System. This attribute identifies an Aggregator instance among the subordinate managed objects of the containing object. This value is read-only. This is the same value as the dot3adAggIndex in the dot3adAggTable." REFERENCE "IEEE 802.3 Section 30.7.1.1.1" ::= { cpc6600TrunkGroupTableEntry 1 } cpc6600TrunkGroupTableRule OBJECT-TYPE SYNTAX INTEGER { srcMAC(1), destMAC(2), srcXORDestMAC(3), srcIP(4), destIP(5), srcXORDestIP(6) } ACCESS read-write STATUS mandatory DESCRIPTION "The Rule to be applied to this Link Aggregator's Trunk Group Table. The rules are based on the following selections SrcMAC (1), means that the last three bits of the Source MAC Address are used to index the Trunk Group to get the destination port. DestMAC (2), means the last three bits of the Destination MAC Address are used to index into the Trunk Group to get the destination port. SrcXORDestMAC (3), means that the last three bits of the Source MAC Address are logically XORed with the last three bits of the Destination MAC Address and used to index into the Trunk Group to get the destination port. SrcIP (4), means the last three bits of the Source IP Address are used to index into the Trunk Group to get the destination port. DestIP (5), means the last three bits of the Destination IP Address are used to index into the Trunk Group to get the destination port. SrcXORDestIP (6), means the last three bits of the Source IP Address are logically XORed with the last three bits of the Destination IP Address and used to index into the Trunk Group to get the destination port. This rule defines the distribution algorithm applied to the aggregated link." ::= { cpc6600TrunkGroupTableEntry 2 } cpc6600LinkStateTable OBJECT-TYPE SYNTAX SEQUENCE OF cpc6600LinkStateTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains the Link State Table Entry that defines the state of each ports link." ::= { cpc6600ArchTrunkGroup 2 } cpc6600LinkStateTableEntry OBJECT-TYPE SYNTAX cpc6600LinkStateTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of the link states. This is indexed by the ifIndex of the Aggregator, which is also the dot3adAggIndex." INDEX { cpc6600LinkStateAggIndex } ::= { cpc6600LinkStateTable 1 } cpc6600LinkStateTableEntry ::= SEQUENCE { cpc6600LinkStateAggIndex INTEGER, cpc6600LinkState INTEGER, cpc6600AggregateOrIndividual INTEGER, cpc6600lagStaticNoTimeoutOnOff INTEGER } cpc6600LinkStateAggIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The unique identifier allocated to this Aggregator by the local System. This attribute identifies an Aggregator instance among the subordinate managed objects of the containing object." ::= { cpc6600LinkStateTableEntry 1 } cpc6600LinkState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-write STATUS mandatory DESCRIPTION " The state of this Link Aggregator port." ::= { cpc6600LinkStateTableEntry 2 } cpc6600AggregateOrIndividual OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION " The state of this Link Aggregator port. Indicating whether the Aggregation Port is able to Aggregate ('TRUE') or is only able to operate as an Individual link ('FALSE')." ::= { cpc6600LinkStateTableEntry 3 } cpc6600lagStaticNoTimeoutOnOff OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { disable } Enable/Disable Link Aggregation timeout on a port. Setting a port to enable(1) affects it such that once a link aggregation is formed using a regular LACPDUs exchange mechanism, the port will stay in the aggregation even if it stops receiving LACPDUs from its link partner. In other words, port set to be enable(1) will no longer timeout its Link Aggregation settings once the aggregation is formed. Setting a port to disable(2) restores its regular LAG operation. By default all ports are set to disable(2)." ::= { cpc6600LinkStateTableEntry 4 } -- ------------------------------------------------------------- -- Private Trunk Group Ends -- ------------------------------------------------------------- -- -- Chip Group Begins -- cpc6600ChipStub OBJECT-TYPE SYNTAX INTEGER { noop(1), chip-value2(2), chip-value3(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is a placeholder for the cpc6600ChipGroup." ::= { cpc6600ChipGroup 1 } -- -- Chip Group Ends -- -- -- Sample cpc6600 Enterprise TRAP -- cpc6600IntegrityTestTrap TRAP-TYPE ENTERPRISE cpc6600 DESCRIPTION "A cpc6600IntegrityTestTrap trap is sent when the value of cpc6600IntegrityTestAction was set to sendTrap. Trap includes a time stamp, objects cpc6600IntegrityTestID, cpc6600IntegrityTestName, and a unique ERROR code." ::= 1 -- -- STP Group Begins -- -- This group provides the SNMP user the capabilites to enable/disable -- Fast Uplink and Fast Port Spanning Tree features. -- -- cpc6600FastUplink OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { disable } This object is used to enable/disable the Fast Uplink option. " ::= { cpc6600StpGroup 1 } cpc6600StpFastPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600StpFastPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of valid port entries and their fast port state." ::= { cpc6600StpGroup 2 } cpc6600StpFastPortEntry OBJECT-TYPE SYNTAX Cpc6600StpFastPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of ports." INDEX { cpc6600StpFastPortIndex } ::= { cpc6600StpFastPortTable 1 } Cpc6600StpFastPortEntry ::= SEQUENCE { cpc6600StpFastPortIndex INTEGER, cpc6600StpFastPort INTEGER } cpc6600StpFastPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies the port entry in the Stp Fast Port Table." ::= { cpc6600StpFastPortEntry 1 } cpc6600StpFastPort OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { default=disable:all } The state of the fast port for this port entry." ::= { cpc6600StpFastPortEntry 2 } -- -- FS Group Begins -- -- This group provides the SNMP user the capabilites to enable/disable -- DHCP Server feature and other typical UNIX shell commands to manipulate -- File System I/O. -- -- cpc6600FsCopyTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600FsCopyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of valid file system copy command entries." ::= { cpc6600FsGroup 1 } cpc6600FsCopyEntry OBJECT-TYPE SYNTAX Cpc6600FsCopyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of copy commands." INDEX { cpc6600FsCopyIndex } ::= { cpc6600FsCopyTable 1 } Cpc6600FsCopyEntry ::= SEQUENCE { cpc6600FsCopyIndex INTEGER, cpc6600FsCopySrcFile DisplayString, cpc6600FsCopyDestFile DisplayString, cpc6600FsCopyStatus FsCommandStatus } cpc6600FsCopyIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this copy command entry in the file system command table." ::= { cpc6600FsCopyEntry 1 } cpc6600FsCopySrcFile OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The full path file name of the source file for this file system copy command entry." ::= { cpc6600FsCopyEntry 2 } cpc6600FsCopyDestFile OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The full path file name of the destination file for this file system copy command entry." ::= { cpc6600FsCopyEntry 3 } cpc6600FsCopyStatus OBJECT-TYPE SYNTAX FsCommandStatus ACCESS read-write STATUS mandatory DESCRIPTION "The status of this copy command entry." ::= { cpc6600FsCopyEntry 4 } cpc6600FsMoveTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600FsMoveEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of valid file system Move command entries." ::= { cpc6600FsGroup 2 } cpc6600FsMoveEntry OBJECT-TYPE SYNTAX Cpc6600FsMoveEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Move commands." INDEX { cpc6600FsMoveIndex } ::= { cpc6600FsMoveTable 1 } Cpc6600FsMoveEntry ::= SEQUENCE { cpc6600FsMoveIndex INTEGER, cpc6600FsMoveSrcFile DisplayString, cpc6600FsMoveDestFile DisplayString, cpc6600FsMoveStatus FsCommandStatus } cpc6600FsMoveIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this Move command entry in the file system command table." ::= { cpc6600FsMoveEntry 1 } cpc6600FsMoveSrcFile OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The full path file name of the source file for this file system Move command entry." ::= { cpc6600FsMoveEntry 2 } cpc6600FsMoveDestFile OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The full path file name of the destination file for this file system Move command entry." ::= { cpc6600FsMoveEntry 3 } cpc6600FsMoveStatus OBJECT-TYPE SYNTAX FsCommandStatus ACCESS read-write STATUS mandatory DESCRIPTION "The status of this Move command entry." ::= { cpc6600FsMoveEntry 4 } cpc6600FsRemoveTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600FsRemoveEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of valid file system Remove command entries." ::= { cpc6600FsGroup 3 } cpc6600FsRemoveEntry OBJECT-TYPE SYNTAX Cpc6600FsRemoveEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Remove commands." INDEX { cpc6600FsRemoveIndex } ::= { cpc6600FsRemoveTable 1 } Cpc6600FsRemoveEntry ::= SEQUENCE { cpc6600FsRemoveIndex INTEGER, cpc6600FsRemoveFile DisplayString, cpc6600FsRemoveStatus FsCommandStatus } cpc6600FsRemoveIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this Remove command entry in the file system command table." ::= { cpc6600FsRemoveEntry 1 } cpc6600FsRemoveFile OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The full path file name of the source file for this file system Remove command entry." ::= { cpc6600FsRemoveEntry 2 } cpc6600FsRemoveStatus OBJECT-TYPE SYNTAX FsCommandStatus ACCESS read-write STATUS mandatory DESCRIPTION "The status of this Remove command entry." ::= { cpc6600FsRemoveEntry 4 } cpc6600FsRemoteTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600FsRemoteEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of valid remote filesystem parameters necessary to perform a remote filesystem mount and copy command entries." ::= { cpc6600FsGroup 4 } cpc6600FsRemoteEntry OBJECT-TYPE SYNTAX Cpc6600FsRemoteEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Remote parameter commands." INDEX { cpc6600FsRemoteIndex } ::= { cpc6600FsRemoteTable 1 } Cpc6600FsRemoteEntry ::= SEQUENCE { cpc6600FsRemoteIndex INTEGER, cpc6600FsRemoteLocalMountPoint DisplayString, cpc6600FsRemoteUserName DisplayString, cpc6600FsRemotePassword DisplayString, cpc6600FsRemoteHostIP IpAddress, cpc6600FsRemoteFlagType FsRemoteFlagType, cpc6600FsRemoteStatus FsCommandStatus } cpc6600FsRemoteIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this Remote command entry in the file system command table." ::= { cpc6600FsRemoteEntry 1 } cpc6600FsRemoteLocalMountPoint OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The name of the local mount point for this file system Remote command entry." ::= { cpc6600FsRemoteEntry 2 } cpc6600FsRemoteUserName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The User Name with permission to do a transfer from this remote host filesystem for this Remote command entry." ::= { cpc6600FsRemoteEntry 3 } cpc6600FsRemotePassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The password this user name applies to do the transfer of the source file for this Remote command entry." ::= { cpc6600FsRemoteEntry 4 } cpc6600FsRemoteHostIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the host remote host machine for this Remote command entry." ::= { cpc6600FsRemoteEntry 5 } cpc6600FsRemoteFlagType OBJECT-TYPE SYNTAX FsRemoteFlagType ACCESS read-write STATUS mandatory DESCRIPTION "The transfer method (1) rsh or (2)ftp applied to the source file for this Remote command entry." ::= { cpc6600FsRemoteEntry 6 } cpc6600FsRemoteStatus OBJECT-TYPE SYNTAX FsCommandStatus ACCESS read-write STATUS mandatory DESCRIPTION "The status of this Remote command entry." ::= { cpc6600FsRemoteEntry 7 } cpc6600FsTftpCopyTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600FsTftpCopyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of valid tftp filesystem parameters necessary to perform a tftp copy command." ::= { cpc6600FsGroup 5 } cpc6600FsTftpCopyEntry OBJECT-TYPE SYNTAX Cpc6600FsTftpCopyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Remote parameter commands." INDEX { cpc6600FsTftpCopyIndex } ::= { cpc6600FsTftpCopyTable 1 } Cpc6600FsTftpCopyEntry ::= SEQUENCE { cpc6600FsTftpCopyIndex INTEGER, cpc6600FsTftpCopyAddress IpAddress, cpc6600FsTftpCopySrcFileName DisplayString, cpc6600FsTftpCopyDestFileName DisplayString, cpc6600FsTftpCopyStatus FsCommandStatus } cpc6600FsTftpCopyIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this tftp command entry in the file system command table." ::= { cpc6600FsTftpCopyEntry 1 } cpc6600FsTftpCopyAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Set IP Address for the TFTP server used for copying files." ::= { cpc6600FsTftpCopyEntry 2 } cpc6600FsTftpCopySrcFileName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..255)) ACCESS read-write STATUS mandatory DESCRIPTION "Set TFTP file path and name of source file." ::= { cpc6600FsTftpCopyEntry 3 } cpc6600FsTftpCopyDestFileName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..255)) ACCESS read-write STATUS mandatory DESCRIPTION "Set TFTP file path and name of destination file." ::= { cpc6600FsTftpCopyEntry 4 } cpc6600FsTftpCopyStatus OBJECT-TYPE SYNTAX FsCommandStatus ACCESS read-write STATUS mandatory DESCRIPTION "The status of this tftp command entry." ::= { cpc6600FsTftpCopyEntry 5 } -- -- User Variable Group Begins -- -- This group provides the SNMP user the capabilites to save -- some user defined variables in nvram -- -- cpc6600UsrVarIntTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600UsrVarIntTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of valid user defined integer variables to be saved." ::= { cpc6600UsrVarGroup 1 } cpc6600UsrVarIntTableEntry OBJECT-TYPE SYNTAX Cpc6600UsrVarIntTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of user defined integer variables." INDEX { cpc6600UsrVarIntIndex } ::= { cpc6600UsrVarIntTable 1 } Cpc6600UsrVarIntTableEntry ::= SEQUENCE { cpc6600UsrVarIntIndex INTEGER, cpc6600UsrVarInteger INTEGER } cpc6600UsrVarIntIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this user defined integer variable." ::= { cpc6600UsrVarIntTableEntry 1 } cpc6600UsrVarInteger OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 0 } the value of the user defined integer to be saved in nvram." ::= { cpc6600UsrVarIntTableEntry 2 } cpc6600UsrVarStringTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600UsrVarStringTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "DURABLE: { ' ' } A list of valid user defined string variables to be saved." ::= { cpc6600UsrVarGroup 2 } cpc6600UsrVarStringTableEntry OBJECT-TYPE SYNTAX Cpc6600UsrVarStringTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of user defined string variables." INDEX { cpc6600UsrVarStringIndex } ::= { cpc6600UsrVarStringTable 1 } Cpc6600UsrVarStringTableEntry ::= SEQUENCE { cpc6600UsrVarStringIndex INTEGER, cpc6600UsrVarString DisplayString } cpc6600UsrVarStringIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this user defined string variable." ::= { cpc6600UsrVarStringTableEntry 1 } cpc6600UsrVarString OBJECT-TYPE SYNTAX DisplayString (SIZE (1..255)) ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE { ' ' } the value of the user defined string to be saved in nvram. The value is treated as an ASCII string and must be terminated with a '\0'." ::= { cpc6600UsrVarStringTableEntry 2 } -- -- -- Port Mirroring -- -- This group provides the SNMP user the capabilites to enable/disable -- Port Mirroring feature and to set up the mirrored port(s) and mirror-to -- port and the bcm transfer mode type. -- -- cpc6600PortMirrorPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600PortMirrorPortTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of ports on this system. If ingress/egress traffic is to be captured from this port and mirrored to the mirrored-to port, then this port will be enabled(1), else it will be disabled (2)." ::= { cpc6600PortMirrorGroup 1 } cpc6600PortMirrorPortTableEntry OBJECT-TYPE SYNTAX Cpc6600PortMirrorPortTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Ingress/Egress ports that are either enabled or disabled." INDEX { cpc6600PortMirrorPortIndex } ::= { cpc6600PortMirrorPortTable 1 } Cpc6600PortMirrorPortTableEntry ::= SEQUENCE { cpc6600PortMirrorPortIndex INTEGER, cpc6600PortMirrorEgressPortState PortMirrorState, cpc6600PortMirrorIngressPortState PortMirrorState } cpc6600PortMirrorPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this Ingress/Egress port." ::= { cpc6600PortMirrorPortTableEntry 1 } cpc6600PortMirrorEgressPortState OBJECT-TYPE SYNTAX PortMirrorState ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { default:disable:all } The state enabled(1)/disabled(2) of this port whose out going packets will be sent to the mirrored-to port." ::= { cpc6600PortMirrorPortTableEntry 2 } cpc6600PortMirrorIngressPortState OBJECT-TYPE SYNTAX PortMirrorState ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { default:disable:all } The state enabled(1)/disabled(2) of this port whose in coming packets will be sent to the mirrored-to port." ::= { cpc6600PortMirrorPortTableEntry 3 } cpc6600PortMirrorMirroredToPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 1 } The mirror-to port, that receives the traffic from mirrored egress and ingress port(s) specified." ::= { cpc6600PortMirrorGroup 3 } cpc6600PortMirrorTransferMode OBJECT-TYPE SYNTAX PortMirrorModes ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 1 } The type of traffic to be mirrored. The choices are; bcmMirrorDisable(1) - no mirror enabled, bcmMirrorL2(2) - mirror only Layer-2 Switched Traffic, bcmMirrorL3(3) - mirror Layer-3 and Layer-2 Switched Traffic" ::= { cpc6600PortMirrorGroup 4 } cpc6600PortMirrorCPU OBJECT-TYPE SYNTAX INTEGER (0..26) ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 0 } This value when set to a zero means the feature is disabled. When set to a port number, causes packets sent by the CPU to also be sent to the port number." ::= { cpc6600PortMirrorGroup 5 } -- Packet Threshold setting requries 4 scalars be set the value rate and -- the type. cpc6600PktThresholdRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { '03FFFF'H } The packet threshold rate is used for detection and suppression of Broadcast storms. The rate limit value must be specified in units of packets per second, beyond, which the ingress starts discarding packets (default 0x3ffff)" ::= { cpc6600PktThresholdGroup 1 } cpc6600PktThresholdDLFOnOff OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { disable } This object allows the user to enable/disable the packet rate control for Destination Lookup Failure(DLF) (aka Flooding of Unknown Destination Address)." ::= { cpc6600PktThresholdGroup 2 } cpc6600PktThresholdBroadcastOnOff OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { disable } The packet threshold type is used for detection and suppression of Broadcast storms. It allows the user to enable/disable the packet rate control for Broadcast packets." ::= { cpc6600PktThresholdGroup 3 } cpc6600PktThresholdMulticastOnOff OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { disable } The packet threshold type is used for detection and suppression of Multiccast storms. It allows the user to enable/disable the packet rate control for Multiccast packets." ::= { cpc6600PktThresholdGroup 4 } -- -- Integrity Test Group -- -- This group is meant to be a collection of controls and data -- that configure the integrity testing features of this device -- cpc6600IntegrityTestTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600IntegrityTestTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of integrity test entries." ::= { cpc6600IntegrityTestGroup 1 } cpc6600IntegrityTestTableEntry OBJECT-TYPE SYNTAX Cpc6600IntegrityTestTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the list of integrity tests." INDEX { cpc6600IntegrityTestID } ::= { cpc6600IntegrityTestTable 1 } Cpc6600IntegrityTestTableEntry ::= SEQUENCE { cpc6600IntegrityTestID INTEGER, cpc6600IntegrityTestLevel INTEGER, cpc6600IntegrityTestErrorCode INTEGER, cpc6600IntegrityTestName DisplayString, cpc6600IntegrityTestOnOff INTEGER } cpc6600IntegrityTestID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this entry in the integrity test table." ::= { cpc6600IntegrityTestTableEntry 1 } cpc6600IntegrityTestLevel OBJECT-TYPE SYNTAX INTEGER { levelOne(1), levelTwo(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This integrity test is a member of the set of integrity tests within this level. Level one tests run more frequently than level two tests. " ::= { cpc6600IntegrityTestTableEntry 2 } cpc6600IntegrityTestErrorCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An unique error code produced when this test fails and a variable binding in a trap if one is produced." ::= { cpc6600IntegrityTestTableEntry 3 } cpc6600IntegrityTestName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..128)) ACCESS read-only STATUS mandatory DESCRIPTION "The name of this integrity test." ::= { cpc6600IntegrityTestTableEntry 4 } cpc6600IntegrityTestOnOff OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { on } Turn this test on or off." ::= { cpc6600IntegrityTestTableEntry 5 } cpc6600IntegrityTestActionTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600IntegrityTestActionTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of integrity test ids entries." ::= { cpc6600IntegrityTestGroup 2 } cpc6600IntegrityTestActionTableEntry OBJECT-TYPE SYNTAX Cpc6600IntegrityTestActionTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of integrity test actions." INDEX { cpc6600IntegrityTestID } ::= { cpc6600IntegrityTestActionTable 1 } Cpc6600IntegrityTestActionTableEntry ::= SEQUENCE { cpc6600IntegrityTestActionIgnore INTEGER, cpc6600IntegrityTestActionLogErrorMsg INTEGER, cpc6600IntegrityTestActionRebootSwitch INTEGER, cpc6600IntegrityTestActionSendTrap INTEGER, cpc6600IntegrityTestActionHaltSystem INTEGER, cpc6600IntegrityTestActionSysOffline INTEGER } cpc6600IntegrityTestActionIgnore OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { off } If this object is on(1), then the action to take upon the agent receiving an error event from this integrity test entry, would be to ignore the event." ::= { cpc6600IntegrityTestActionTableEntry 1 } cpc6600IntegrityTestActionLogErrorMsg OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { on } If this object is on(1), then the action to take upon the agent receiving an error event from this integrity test entry, would be to log an error message." ::= { cpc6600IntegrityTestActionTableEntry 2 } cpc6600IntegrityTestActionRebootSwitch OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { off } If this object is on(1), then the action to take upon the agent receiving an error event from this integrity test entry, would be to reboot the switch." ::= { cpc6600IntegrityTestActionTableEntry 3 } cpc6600IntegrityTestActionSendTrap OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { off } If this object is on(1), then the action to take upon the agent receiving an error event from this integrity test entry, would be to send an SNMP trap." ::= { cpc6600IntegrityTestActionTableEntry 4 } cpc6600IntegrityTestActionHaltSystem OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If this object is on(1), then the action to take upon the agent receiving an error event from this integrity test entry, would be to halt the system." ::= { cpc6600IntegrityTestActionTableEntry 5 } cpc6600IntegrityTestActionSysOffline OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { off } If this object is on(1), then the action to take upon the agent receiving an error event from this integrity test entry, would be to take the system offline." ::= { cpc6600IntegrityTestActionTableEntry 6 } cpc6600IntegrityTestLevelOneOnOff OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { on } Turn on/off all LevelOne integrity tests." ::= { cpc6600IntegrityTestGroup 3 } cpc6600IntegrityTestLevelTwoOnOff OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE : { off } Turn on/off all LevelTwo integrity tests." ::= { cpc6600IntegrityTestGroup 4 } cpc6600IntegrityTestLevelOneTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "DURABLE: { 200 } The time in 100 milli-seconds that is sleeps between the level one integrity tests." ::= { cpc6600IntegrityTestGroup 5 } -- -- User Inclusive Filter Group -- -- This group is meant to be a collection of filters -- that can be applied to an incoming or outgoing packet -- that are added by the user. -- cpc6600UserInclusiveFilterMaskTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600UserInclusiveFilterMaskTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of 8 filter masks to be applied to incoming or outgoing packets." ::= { cpc6600UserInclusiveFilterGroup 1 } cpc6600UserInclusiveFilterMaskTableEntry OBJECT-TYPE SYNTAX Cpc6600UserInclusiveFilterMaskTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of inclusive filter masks." INDEX { cpc6600UserInclusiveFilterMaskID } ::= { cpc6600UserInclusiveFilterMaskTable 1 } Cpc6600UserInclusiveFilterMaskTableEntry ::= SEQUENCE { cpc6600UserInclusiveFilterMaskID INTEGER, cpc6600UserInclusiveFilterMaskIngressPort INTEGER, cpc6600UserInclusiveFilterMaskEgressPort INTEGER, cpc6600UserInclusiveFilterMask FilterMask, cpc6600UserInclusiveFilterMaskStatus Cpc6600RowStatus } cpc6600UserInclusiveFilterMaskID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this entry in the inclusive filter mask table." ::= { cpc6600UserInclusiveFilterMaskTableEntry 1 } cpc6600UserInclusiveFilterMaskIngressPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This field is a 6-bit mask that is used to identify which ingress ports the Packet Filter should apply to. The ingress port number is 'and-ed' with this value and compared with the value in the cpc6600UserInclusiveFilterRulesIngressPort field. Typically, you set both of these objects to zero if the ingress port is any port. You set the cpc6600UserInclusiveFilterMaskIngressPort to 0x3f (63) and the cpc6600UserInclusiveFilterRulesIngressPort field to a particular port number (zero-based) to select a particlar ingress port." ::= { cpc6600UserInclusiveFilterMaskTableEntry 2 } cpc6600UserInclusiveFilterMaskEgressPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This field is a 6-bit mask that is used to identify which egress ports the Packet Filter should apply to. The egress port number is 'and-ed' with this value and compared with the value in the cpc6600UserInclusiveFilterRulesEgressPort field. Typically, you set both of these objects to zero if the egress port is any port. You set the cpc6600UserInclusiveFilterMaskEgressPort to 0x3f (63) and the cpc6600UserInclusiveFilterRulesEgressPort field to a particular port number (zero-based) to select a particlar egress port." ::= { cpc6600UserInclusiveFilterMaskTableEntry 3 } cpc6600UserInclusiveFilterMask OBJECT-TYPE SYNTAX FilterMask ACCESS read-write STATUS mandatory DESCRIPTION "A filter value to be applied to every incoming packet. The first 512 bits of the packet are 'and-ed' with this value and compared to the value of a cpc6600UserInclusiveFilterRulesFilterMask entry." ::= { cpc6600UserInclusiveFilterMaskTableEntry 4 } cpc6600UserInclusiveFilterMaskStatus OBJECT-TYPE SYNTAX Cpc6600RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry. A row in this table must be created using the createAndWait(5) action state (i.e., createAndGo(4) is not supported). This object can only be set to active(1) after all objects for this row are valid. To delete an entry set to delete(6). Objects in this table row can be changed when this object is notReady(3)." ::= { cpc6600UserInclusiveFilterMaskTableEntry 5 } cpc6600UserInclusiveFilterRulesTable OBJECT-TYPE SYNTAX SEQUENCE OF Cpc6600UserInclusiveFilterRulesTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of 128 inclusive filter rules to be applied to incoming or outgoing packets." ::= { cpc6600UserInclusiveFilterGroup 2 } cpc6600UserInclusiveFilterRulesTableEntry OBJECT-TYPE SYNTAX Cpc6600UserInclusiveFilterRulesTableEntry ACCESS not-accessible STATUS mandatory D